Appliances properties: Oranier Heiztechnik GmbH - OR HKH 50 - 1862

Master data
Date of entry Feb 2, 2022
Manufacturer Oranier Heiztechnik GmbH
Model OR HKH 50
Product code 1862
Nominal heat output [kW] 7
Declared nominal space heating output [kW] 7
Continuous burning appliance hyphen
Type test standard DIN EN 12815
Year of testing 2019
Test laboratory KONTROL 94 Ltd.
Number of test laboratory 32
Number of test report NB 1879-K-17-2019
Flue gas values
  Wood
Flue gas mass flow [g/s] 7.2
Flue gas mass flow [g/s] 258
Necessary flue draught [Pa] 10.5
Further important characteristics of the appliance
Suitability for installation to a shared flue1) hyphen
Connectivity to the central heating system hyphen
General technical approval for room sealed operation hyphen

1) For unsealed operation it is possible to install the appliances to a shared flue system (please see installation manual).

On behalf of the manufacturer, the HKI Industrieverband e.V. hereby confirms compliance with the respective requirements* in accordance with 1.BImSchV. The type test report of the fireplace has been submitted to the HKI Industrieverband e.V.

* A green check mark with a „1“ indicates that the requirements of the 1st BImSchV are fulfilled, a green check mark with a „2“ indicates that the 2nd level of the 1st BImSchV is fulfilled. A yellow check mark shows that the transitional regulation of the 1st BImSchV is fulfilled and a red line means that the 1st BImSchV is not fulfilled.

Evaluation of emission data and efficiency Wood
EU-Cooker according to EN 12815 Evaluation  
EU - Regulation (EU) 2015/1185 (Ecodesign) Details
D - 1.BImSchV
Grandfathering
Details    Explanation
A - Austrian regulation referred to Art. 15a B-VG Details
CH - Swiss clean air act Details
F - Crédit d’impôt à la transition énergétique Details
I - Italian Decree No. 186 Details
Evaluation of emission data and efficiency Lignite briquettes
Norm : Cookers Evaluation  
D - 1.BImSchV Details    Explanation
Evaluation of emission data and efficiency Pellets
Norm : Cookers Evaluation  
D - 1.BImSchV Details    Explanation
Emission evaluation legend
Compliant with the requirements of the 2nd stage of the 1.BImSchV (only for Germany)
Compliant with the requirements of the 1st stage of the 1.BImSchV (only for Germany)
Compliant with the requirements of the Austrian Agreement pursuant to Art. 15a B-VG from 2015 (applies only to Austria)
Compliant with the requirements for the „Crédit d’impôt“ promotion in France, the fireplace complies with the classification 7* of the Flamme Verte Label
Compliant with the requirements for the „Crédit d’impôt“ promotion in France, the fireplace complies with the classification 6* of the Flamme Verte Label
Compliant with the requirements for the „Crédit d’impôt“ promotion in France, the fireplace complies with the classification 5* of the Flamme Verte Label
Compliant with the requirements of the 1 star stage in Italy.
Compliant with the requirements of the 2 star stage in Italy.
Compliant with the requirements of the 3 star stage in Italy.
Compliant with the requirements of the 4 star stage in Italy.
Compliant with the requirements of the 5 star stage in Italy.
Fulfils the requirements
Complies with requirements of the transition ruling (1.BImSchV)
Requirements are not fulfilled
No information/unknown
No measuring values are available for this fuel, operation with this fuel is not permitted
No symbol means that there are no requirements.
Here you will find further information